Engineering items: Difference between revisions
Jump to navigation
Jump to search
→Equipment
imported>Kingofkosmos (→Items) |
imported>Kingofkosmos |
||
Line 140: | Line 140: | ||
=Equipment= | =Equipment= | ||
{{anchor|SMES Cell}} | {{anchor|SMES Cell}} | ||
{{Item | {{Item | ||
Line 161: | Line 149: | ||
|usedfor = Storing and distributing power | |usedfor = Storing and distributing power | ||
|strategy = Set an input (must be lower value than the input from wire, otherwise nothing goes in!), set on output (preferably smaller than the input so something will actually be stored in the cell), and watch the station flourish! | |strategy = Set an input (must be lower value than the input from wire, otherwise nothing goes in!), set on output (preferably smaller than the input so something will actually be stored in the cell), and watch the station flourish! | ||
|description = Huge, immovable cell/battery for power distributing purposes. Maximum capacity 5 megawatts. | |description = Huge, immovable cell/battery for power distributing purposes. Maximum capacity 5 megawatts.<br> | ||
Left lights represent how much of the SMES is loaded.<br> | |||
The top right light shows the input power status. If it's off = none, red = on but receiving no power, blinking yellow = receiving power and loading.<br> | |||
The middle right light shows the output power status. If it's off = not outputting power, green = outputting power. | |||
}} | }} | ||
Line 176: | Line 167: | ||
}} | }} | ||
{{anchor|APC}} | |||
{{Item | |||
|bgcolor1 = #cce6ff | |||
|bgcolor2 = #99ccff | |||
|name = APC | |||
|image = APC2.gif | |||
|foundin = Every room with power | |||
|usedfor = Controlling the power for a sector on the station. | |||
|strategy = Have engineering access, swipe your ID on it to unlock it and choose your action. | |||
|description = Actions available on the APC: | |||
<b>Main Breaker: On/Off</b> - Toggles power to the room | |||
<br><b>Equipment: Auto/On/Off</b> - Toggles power to computers, doors, and other electronic equipment. | |||
<br><b>Lighting: Auto/On/Off</b> - Toggles power to lighting in the area. | |||
<br><b>Environmental: Auto/On/Off</b> - Toggles power to the ventilation in the area, as well as the Air Alarm. | |||
<br><b>Cover Lock: Engaged/Disengaged:</b> Provides a cover to protect the battery. | |||
Remember, 'Auto' power settings slowly cuts off each breaker when power runs low (<20 %) in this order: <b>Equipment, Lighting, Environment.</b> | |||
'''''Replacing the APC's Battery''''' | |||
---- | |||
To replace the APC battery, you need an ID with sufficient access to unlock the APC itself.<br> | |||
#Swipe your ID and unlock the interface. | |||
#Open the panel and disengage the cover lock. | |||
#Use a crowbar on the APC to open the cover. | |||
#Take the battery out with a free hand and then place in the new one. | |||
#Close the cover again with your crowbar, re-engage the cover lock and swipe your ID to secure the interface. | |||
}} | |||
{{anchor|Cell Charger}} | |||
{{Item | |||
|bgcolor1 = #cce6ff | |||
|bgcolor2 = #99ccff | |||
|name = Cell Charger | |||
|image = cellcharger.png | |||
|foundin = [[Cargo_Loading_Area|Cargo]], [[Engineering]], [[Primary Tool Storage]], [[Research_Division#Research_Lab|R&D]], [[Robotics_and_Mech_Bay|Robotics]] | |||
|usedfor = Recharging power cells | |||
|strategy = Place power cells into these to charge them up | |||
|description = These will drain power directly from the room's APC unit to fill power cells. Beware with high capacity cells, as they will drain the room's APC completely. Can be secured and unsecured using a wrench. | |||
}} | |||
[[Category:Objects]] | [[Category:Objects]] |