Thermo-Electric Generator: Difference between revisions

No edit summary
Line 10: Line 10:
*The injector in the burn mix chamber needs to be manually turned on and set to max output.
*The injector in the burn mix chamber needs to be manually turned on and set to max output.
*The filter for the burn mix chamber is flipped, so you need to filter O2 and Plasma instead.
*The filter for the burn mix chamber is flipped, so you need to filter O2 and Plasma instead.
*There is no Burn to Waste valve to turn on.
*The last step can easily accidentally introduce the hot loop into the cold loop if not careful.


Adjusted steps:
Adjusted steps:
Line 30: Line 30:
#At '''point 13''', wrench down both of the CO2 canisters.
#At '''point 13''', wrench down both of the CO2 canisters.
#At '''points 14, 15 and 16''', turn on the pumps and max them.
#At '''points 14, 15 and 16''', turn on the pumps and max them.
#Once pressure/heat builds up in the hot loop ''(Indicated by the gas flow meter on the hot loop flashing)'' and the burn mix is over 30,000C ''(view the gas flow meter above the burn chamber)'', turn '''on''' the valve at '''points 17'''.
#Once pressure/heat builds up in the hot loop ''(Indicated by the gas flow meter on the hot loop flashing)'' and the burn mix is over 30,000C ''(view the gas flow meter above the burn chamber)'':
##Un-wrench the canisters at '''point 2'''
##Turn '''off''' the pump at '''point 3'''
##Turn '''on''' the valves at '''points 17 & 18'''.
#It will take some time for the power to build up.
#It will take some time for the power to build up.


System Operators, Wiki Staff
855

edits