Thermo-Electric Generator: Difference between revisions

Jump to navigation Jump to search
(Updates the guide to the one written by User:Wandering Host)
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
=Introduction=
=Introduction=
The Thermo-Electric Generator (TEG) is an atmospherics-based generator that operates on the simple principle of cold air loop plus hot air loop equals power. As long as the set-up is appropriate, the TEG's output will scale up and can make anywhere between almost no power to enough power to satisfy the energy draw of 1000 space stations.
The Thermo-Electric Generator (TEG) is an atmospherics-based generator that operates on the simple principle of cold air loop plus hot air loop equals power. As long as the set-up is appropriate, the TEG's output will scale up and can make anywhere between almost no power to enough power to satisfy the energy draw of 1000 space stations.
=How to Set Up the TEG=
This is a basic setup that will yield estimately 600-800kW which is enough to charge most of the SMES.
<div class="toccolours mw-collapsible mw-collapsed">
'''<span style="color:red">The IceMeta Station is set up differently, follow the guide here instead.</span>'''
<div class="mw-collapsible-content">
[[File:meta_teg.png|thumb|650px]]
Some of the main differences in this setup:
*The injector in the burn mix chamber needs to be manually turned on and set to max output.
*The filter for the burn mix chamber is flipped, so you need to filter O2 and Plasma instead.
*The last step can easily accidentally introduce the hot loop into the cold loop if not careful.
*Due to the outside not being space, the cold loop may eventually warm up from the waste output. This can be remedied by adding some freezers to the cold loop before setting up.
Adjusted steps:
#Screwdriver and wrench the circulators and generator to release them from the ground.
#At '''point 1''', move the circulators and generator to the positions shown, alt-click the circulators to rotate them to the correct orientation.
#Wrench the circulators and generator into place.
#Using a multitool, change the mode of the circulators to the correct mode for each side (''1 tap = cold, 2 taps = hot'').
#Screwdriver shut the circulators and the generator.
#Wrench the center generator to complete the engine assembly.
#At '''point 2''', wrench down all of the CO2 cannisters.
#At '''points 3, 4 and 5''', turn on the pumps and max them.
#At '''point 6''', turn on the filter.
#At '''points 7 and 8''', turn on the pumps and max them.
#At '''point 9''', set the mixer to a burn mix, turn on the mixer to max pressure. ''(The nodes are coloured to determine which node is which gas - normally '''Node 1 = Green = Plasma''', a default mix would be 60/40 oxygen/plasma, different ratios alter heat output and gas production'')''.'' (''NOTE: burn mix is tested to last nearly 50 minutes if you empty both tanks).''
#At '''point 10''', put on a hardsuit and internals, go out the airlock to the south and click on the injector shown. Turn it on and max output.
#At '''point 11''', press the top button to close the blast doors to the burn mix chamber.
#Once some gasses have entered the chamber, press the bottom button at point 11 to ignite the mix.
#At '''point 12''', turn on and set the filter to filter O2 and Plasma. Then turn on the valve just north of the filter.
#At '''point 13''', wrench down both of the CO2 canisters.
#At '''points 14, 15 and 16''', turn on the pumps and max them.
#Once pressure/heat builds up in the hot loop ''(Indicated by the gas flow meter on the hot loop flashing)'' and the burn mix is over 30,000C ''(view the gas flow meter above the burn chamber)'':
##Un-wrench the canisters at '''point 2'''
##Turn '''off''' the pump at '''point 3'''
##Turn '''on''' the valves at '''points 17 & 18'''.
#It will take some time for the power to build up.
</div>
</div>
[[File:TEG.png|650px|thumb]]
[[File:TEG.png|650px|thumb]]
=How to Set Up the TEG=
#{{anchor|step one}}Screwdriver and wrench the circulators and generator to release them from the ground.
#{{anchor|step one}}Screwdriver and wrench the circulators from the ground.
#At '''point 1''', move the circulators and generator to the positions shown, alt-click the circulators to rotate them to the correct orientation.
#Move the circulators to the squares beside the generator. Wrench down once in place. (''make sure to orientate them with the notches beside the generator before wrenching [alt-click to turn]).''
#Wrench the circulators and generator into place.
#Now in place we need to multi tool the circulators. Changing the mode, once done then screwdriver shut (''1 tap = cold 2 taps = hot'').
#Using a multitool, change the mode of the circulators to the correct mode for each side (''1 tap = cold, 2 taps = hot'').
#Wrench down the center to complete the engine assembly.
#Screwdriver shut the circulators and the generator.
#Turn on pumps and max them, open valves, press buttons if need be (''Follow the orange and cyan pipes.'').
#Wrench the center generator to complete the engine assembly.
#Wrench down some of the CO2 canisters to the connectors and turn on pumps.
#At '''point 2''', wrench down all of the CO2 cannisters.
#Go to the incinerator and check if the blast doors are closed. If not, then press the buttons on the table.
#At '''points 3, 4 and 5''', turn on the pumps and max them.
#Open up the air alarm and enter the scrubber menu, find the scrubber in the incinerator chamber and set range: '''Expanded'''. (skip if there isnt a scrubber)
#At '''point 6''', turn on the filter.
#Prepare burn mix, (''different ratios alter heat output and gas production''), then turn on mixer to max pressure. Then turn on igniter. (''NOTE: burn mix is tested to last nearly 50 minutes if you empty both tanks).''
#At '''points 7 and 8''', turn on the pumps and max them.
#At '''point 9''', set the mixer to a burn mix, turn on the mixer to max pressure. ''(The nodes are coloured to determine which node is which gas - normally '''Node 1 = Green = Plasma''', a default mix would be 60/40 oxygen/plasma, different ratios alter heat output and gas production'')''.'' (''NOTE: burn mix is tested to last nearly 50 minutes if you empty both tanks).''
#At '''point 10''', turn on the pump and max it
#At '''point 11''', press the top button to close the blast doors to the burn mix chamber.
#Once some gasses have entered the chamber, press the bottom button at point 11 to ignite the mix.
#At '''point 12''', turn on and set the filter to filter out CO2, H2O, Tritium, and Pluoxium.
#At '''point 13''', wrench down both of the CO2 canisters.
#At '''points 14, 15 and 16''', turn on the pumps and max them.
#Once pressure/heat builds up in the hot loop ''(Indicated by the gas flow meter on the hot loop flashing)'' and the burn mix is over 30,000C ''(view the gas flow meter above the burn chamber)'', turn '''on''' the valves at '''points 17 and 18'''.
#It will take some time for the power to build up.
 
=TEG Fundamentals=
=TEG Fundamentals=
The Thermo-Electric Generator is a simple engine. This engine uses hot and cold gas, (''hot and cold sides of the circulators'') to generate energy. To make more power, you will need to scale the hot and cold gasses and maintain the temperature difference between them. The limiting factor being how the engine is set up and having too great of a difference in gas temperature. A great difference in temperature can overpower the other circulator, preventing power generation. However, an unmodified engine will usually lead you into the biggest, most common problem: clogs.
The Thermo-Electric Generator is a simple engine. This engine uses hot and cold gas, (''hot and cold sides of the circulators'') to generate energy. To make more power, you will need to scale the hot and cold gasses and maintain the temperature difference between them. The limiting factor being how the engine is set up and having too great of a difference in gas temperature. A great difference in temperature can overpower the other circulator, preventing power generation. However, an unmodified engine will usually lead you into the biggest, most common problem: clogs.
Line 33: Line 81:
*Increase coolness to the cold loop by adding more gas or expand cooling loop.
*Increase coolness to the cold loop by adding more gas or expand cooling loop.
''NOTE: if these don't work then it might be needed to replace the pressure pumps with volume pumps''
''NOTE: if these don't work then it might be needed to replace the pressure pumps with volume pumps''
=Troubleshooting=
=Troubleshooting=
<div class="toccolours mw-collapsible mw-collapsed" style="width:1000px">
<div class="toccolours mw-collapsible mw-collapsed" style="width:1000px">
Line 70: Line 117:
'''Answer:''' It is possible that you set the TEG's cold and hot loops on the wrong side, if true there should have been a short time of a loop indicating some flow before completey stopping, check inside the TEG's display that the cold loop is indeed cold and not hot. If the loops are the wrong way around, un-wrench the TEG apart, open both circulators with a screwdriver, and multitool both circulators, screwdriver both circulators closed then wrench it back together.
'''Answer:''' It is possible that you set the TEG's cold and hot loops on the wrong side, if true there should have been a short time of a loop indicating some flow before completey stopping, check inside the TEG's display that the cold loop is indeed cold and not hot. If the loops are the wrong way around, un-wrench the TEG apart, open both circulators with a screwdriver, and multitool both circulators, screwdriver both circulators closed then wrench it back together.
</div></div>
</div></div>
=Sabotaging The TEG=
=Sabotaging The TEG=
Unfortunately for filthy traitors, the TEG is a safe engine, however that doesn't mean you cannot stop it from producing power.  
Unfortunately for filthy traitors, the TEG is a safe engine, however that doesn't mean you cannot stop it from producing power.  
*Your greatest tool for sabotaging this engine is how daunting the pipe works look, something as simple as turning off the injector from the computer console or turning off the filter will cause the TEG to clog inside the loop and will reduce the power output until the hot loop is non-functional.
*Your greatest tool for sabotaging this engine is how daunting the pipe works look, something as simple as turning off the injector from the computer console or turning off the filter will cause the TEG to clog inside the loop and will reduce the power output until the hot loop is non-functional.


Line 83: Line 128:


*Simply opening the plasma canister at max pressure will start a plasma fire in the room that will destroy the TEG and the observation computer, this option should be done with care as atmos fuckery will often raise the ire of the admins.
*Simply opening the plasma canister at max pressure will start a plasma fire in the room that will destroy the TEG and the observation computer, this option should be done with care as atmos fuckery will often raise the ire of the admins.
There are many other creative ways to mess around with the TEG, just take care to not violate the murder bone rules, whilst a TEG won't explode its high-end damage is station ending, more so than that of a loose tesla or singularity.
There are many other creative ways to mess around with the TEG, just take care to not violate the murder bone rules, whilst a TEG won't explode its high-end damage is station ending, more so than that of a loose tesla or singularity.
System Operators, Wiki Staff
857