Hacking: Difference between revisions
Jump to navigation
Jump to search
Airlock and APC code requires more attention than I can give now. For the record, ID scan wire does SOMETHING when cut
imported>Steelpoint (→What You'll Need: Added in a alt tool.) |
imported>Kelenius (Airlock and APC code requires more attention than I can give now. For the record, ID scan wire does SOMETHING when cut) |
||
Line 1: | Line 1: | ||
{{Needs revision|reason=Needs updating, verification and info added! (see parts with "???")}} | {{Needs revision|reason=Needs updating, verification and info added! (see parts with "???")}} | ||
== | == Your tools == | ||
[[File:IGloves.png | [[File:IGloves.png|link=Insulated Gloves]] '''[[Insulated Gloves]]''' hackables have power lines, and cutting/pulsing these without gloves can harm you. It's possible to hack without them, but it will be slow, painful, and you'll need ointment. The shock will always be delivered to your hands or legs, so it will never crit you if you're at full health, as limbs can't take more than 75 damage. | ||
[[File:Screwdriver_tool.png | [[File:Screwdriver_tool.png|link=Screwdriver]] '''[[Screwdriver]]''' for opening up panels and the like. A necessary tool. | ||
[[File:Wirecutters.png | [[File:Wirecutters.png|link=Wirecutters]] '''[[Wirecutters]]''' for cutting and mending wires. | ||
= | [[File:Multitool.png|link=Multitool]] '''[[Multitool]]''' for pulsing wires. Not necessary for most hacking, but makes life a lot easier. | ||
[[File:Signaler.png|link=Signaler]] '''[[Signaler]]''' can be used as a ghetto alternative to a Multitool and to pulse wires remotly. Attach one on a wire, then use a second signaler to pulse that wire. | |||
[[File:Signaler.png | |||
== Hackables == | == Hackables == | ||
Line 116: | Line 114: | ||
* '''Use multitools for bolted ''' as they are awesome. First find two wires of importance: the bolts wire, and the main power wire. Pulse a random door to find out the wires. If you get shocked, close that hacking window and move onto another door. Once you got the main power wire, head to an unbolted door, pulse the wire, crowbar it open. You get a larger window of time to crowbar, and you can do it without gloves. If a door is bolted, pulse the bolts wires, and go and cut the power then crowbar it. | * '''Use multitools for bolted ''' as they are awesome. First find two wires of importance: the bolts wire, and the main power wire. Pulse a random door to find out the wires. If you get shocked, close that hacking window and move onto another door. Once you got the main power wire, head to an unbolted door, pulse the wire, crowbar it open. You get a larger window of time to crowbar, and you can do it without gloves. If a door is bolted, pulse the bolts wires, and go and cut the power then crowbar it. | ||
=== [[File:APC2.gif | === [[File:APC2.gif|link=APC]] [[APC]] === | ||
Controls power to its assigned room. All APC breakers can be accessed via Power Monitoring Computers regardless of the lock status, so hope that whoever's fucking with the power isn't paying attention. | Controls power to its assigned room. All APC breakers can be accessed via Power Monitoring Computers regardless of the lock status, so hope that whoever's fucking with the power isn't paying attention. | ||
Line 123: | Line 121: | ||
# Click with an empty hand to access the wiring. | # Click with an empty hand to access the wiring. | ||
# Fiddle with the wires by pulsing to test each one and cutting what you need to. | # Fiddle with the wires by pulsing to test each one and cutting what you need to. | ||
# Screwdriver it back up to toggle lighting, equipment, and atmospherics as you see fit (unless you've killed the power). | # Screwdriver it back up to toggle lighting, equipment, and atmospherics as you see fit (unless you've killed the power). | ||
* Cover lock prevents the APC from opening. If it's off, you can use a crowbar to open the APC. | |||
* Interface lock prevents anyone from using the APC. It is normally removed by swiping an ID card. | |||
{| class="wikitable" style="text-align:center" | {| class="wikitable" style="text-align:center" | ||
Line 136: | Line 134: | ||
|- | |- | ||
!Power (2 wires) | !Power (2 wires) | ||
|Disables power. May shock!||Restores. May shock!|| | |Disables power. May shock!||Restores. May shock!||Disables power for 2 minutes. You must ''cut and mend'' the wire to restore power. | ||
|- | |- | ||
!ID lock | !ID lock | ||
|Disable toggling the lock with an ID card.||Restores.|| | |Disable toggling the lock with an ID card.||Restores.||Unlocks APC interface for 30 seconds. | ||
|- | |- | ||
!AI control | !AI control | ||
|Disables AI control.||Restores.|| | |Disables AI control.||Restores.||''Very briefly'' disables AI control. | ||
|} | |||
{| class="wikitable" style="text-align:center" | |||
|+Status window | |||
!Name | |||
!Status | |||
!Shows that | |||
|- | |||
!rowspan="2"|Lock | |||
|The APC is locked.||APC is locked. | |||
|- | |||
|The APC is unlocked.||APC is unlocked. | |||
|- | |||
!rowspan="2"|Power | |||
|The APCs power has been shorted.||APC is not working. | |||
|- | |||
|The APC is working properly!||APC is working. | |||
|- | |||
!rowspan="2"|AI control | |||
|The 'AI control allowed' light is off.||AI/borgs can't interact with APC. | |||
|- | |||
|The 'AI control allowed' light is on.||AI/borgs can interact with APC. | |||
|} | |} | ||