# Fit your volumetric pumps in place of Waste In and Air to Distro, making sure the red stripe lines up with how the pumps were fitted by default so the flow goes the right way.
# Fit your volumetric pumps in place of Waste In and Air to Distro, making sure the red stripe lines up with how the pumps were fitted by default so the flow goes the right way.
# Volumetric pumps are automatically set to full fucking power so just turn on both of them.
# Volumetric pumps are automatically set to full fucking power so just turn on both of them.
# Set every scrubber in the loop around the room to 4500 kPa. This is full blast.:* You have now completely set up Atmospherics to be beast mode in, like, three minutes. You can also do other stuff, like fit manual valves to the bad gasses to hamper solo-AI floods, and replace other pumps in the bowels of Atmospherics with volume pumps, but really, that five point checklist will do it. Ninety-plus percent of people don't know jack shit about Atmospherics, and it's so easy to set it up so that it actually does shit. It's so rare to see it happen that the CE actually sought me out for praise for doing it this way.:* For AIs, if no organics are around competent/willing to do this manually and your Engiborgs (if you have any) are busy, which is like a guarantee, you can do a simpler version of this; just turn Air to Distro and Waste In up to 4500 kPa and set each scrubber station to 4500 kPa too. It won't be as effective but it's so much better than nothing. Cranking up the air available in the distro loop poses no threat to safety, and in fact makes it harder to start up harmful floods since there's so much good air in the way in there. And since you're the AI, you can now use air vents (and scrubbers) as they were fucking designed to be used; to scrub, drain, and replace air in rooms as necessary, and it fucking works. It is astonishing how little is required to turn a system so often seen as worthless into a helpful part of the station.:* Minor addendum: A maxed volume pump and a maxed normal pump pump at the same rate given ideal circumstances. The difference is the volume pump won't stop pumping once its output end is at 4500 kpa or more. This makes it excellent for waste in, where no matter how much gas the previous fire/atmos experiment clogged the filtering loop with, Waste In is still pumping waste out of the scrubbers pipes, and by extension, helping keep the scrubbers from getting clogged to the point of uselessness.:* For the record, the advice of adding manual valves to the plasma loop will result in you getting yelled at by an admin if there's no evidence that the AI is rogue. It's "Spacing objectives tier", and for good reason.:* Setting up atmos doesn't really matter that much anyway as long as you give the distro loop some pressure. The entire supply and equipment is designed for a space station that's supposed to last month. There's about two instances in which a proper setup is useful: massive hullbreaches which will drain a lot of air (most of which will then uselessly disappear in space anyway) and station wide plasma fires which might fill the waste loop (in which case you're at fault as an atmos tech for not keeping an eye on the system in the first place).
# Set every scrubber in the loop around the room to 4500 kPa. This is full blast.
* You have now completely set up Atmospherics to be beast mode in, like, three minutes. You can also do other stuff, like fit manual valves to the bad gasses to hamper solo-AI floods, and replace other pumps in the bowels of Atmospherics with volume pumps, but really, that five point checklist will do it. Ninety-plus percent of people don't know jack shit about Atmospherics, and it's so easy to set it up so that it actually does shit. It's so rare to see it happen that the CE actually sought me out for praise for doing it this way.
* For AIs, if no organics are around competent/willing to do this manually and your Engiborgs (if you have any) are busy, which is like a guarantee, you can do a simpler version of this; just turn Air to Distro and Waste In up to 4500 kPa and set each scrubber station to 4500 kPa too. It won't be as effective but it's so much better than nothing. Cranking up the air available in the distro loop poses no threat to safety, and in fact makes it harder to start up harmful floods since there's so much good air in the way in there. And since you're the AI, you can now use air vents (and scrubbers) as they were fucking designed to be used; to scrub, drain, and replace air in rooms as necessary, and it fucking works. It is astonishing how little is required to turn a system so often seen as worthless into a helpful part of the station.
* Minor addendum: A maxed volume pump and a maxed normal pump pump at the same rate given ideal circumstances. The difference is the volume pump won't stop pumping once its output end is at 4500 kpa or more. This makes it excellent for waste in, where no matter how much gas the previous fire/atmos experiment clogged the filtering loop with, Waste In is still pumping waste out of the scrubbers pipes, and by extension, helping keep the scrubbers from getting clogged to the point of uselessness.
* For the record, the advice of adding manual valves to the plasma loop will result in you getting yelled at by an admin if there's no evidence that the AI is rogue. It's "Spacing objectives tier", and for good reason.
* Setting up atmos doesn't really matter that much anyway as long as you give the distro loop some pressure. The entire supply and equipment is designed for a space station that's supposed to last month. There's about two instances in which a proper setup is useful: massive hullbreaches which will drain a lot of air (most of which will then uselessly disappear in space anyway) and station wide plasma fires which might fill the waste loop (in which case you're at fault as an atmos tech for not keeping an eye on the system in the first place).
* If you are an atmos tech and want to greatly reduce possibility of harmful atmos manipulations... or if you are an AI and you spotted a guy just turning valves to release plasma to distro:
* If you are an atmos tech and want to greatly reduce possibility of harmful atmos manipulations... or if you are an AI and you spotted a guy just turning valves to release plasma to distro:
:* Open atmospherics console for specific chamber and toggle power on output. 90% of players don't check this console. As AI I laughed many times as sabotagist was running back and forth, checking every pump 3 times, and still no plasma appeared. In this way you can also shut down harmful gases pumping when one is smart and changed pipes under grilles.:* Or put manual valves in front of every harmful gas, switch out some gas pumps for volumetric pumps, and repipe the mixing pipes to disallow the mix tank to provide into the distro. (Setting up Atmos in such a way it can't be sabotaged by the AI before there's a reason to think the AI might sabotage Atmos is not only metagaming, it is also bannable. If you see this happen, adminhelp it!)
** Open atmospherics console for specific chamber and toggle power on output. 90% of players don't check this console. As AI I laughed many times as sabotagist was running back and forth, checking every pump 3 times, and still no plasma appeared. In this way you can also shut down harmful gases pumping when one is smart and changed pipes under grilles.
** Or put manual valves in front of every harmful gas, switch out some gas pumps for volumetric pumps, and repipe the mixing pipes to disallow the mix tank to provide into the distro. (Setting up Atmos in such a way it can't be sabotaged by the AI before there's a reason to think the AI might sabotage Atmos is not only metagaming, it is also bannable. If you see this happen, adminhelp it!)
* You can rotate a pipe in your hand by click on it.
* You can rotate a pipe in your hand by click on it.
* Fire extinguishers fit in firesuit suitstorage.
* Fire extinguishers fit in firesuit suitstorage.